Zhuhai, China — October 2026 — Trap builders and facility teams moving from conventional ultraviolet lamps to LED are usually working inside an existing housing: the fixture, the wiring and the mounting bracket are already fixed. On the TH-UV365T8-10W-Z589-B-TM 0.9PF, a 10 W 365 nm UVA LED tube for mosquito trap lamps, the mechanical envelope is deliberately conventional — Φ25.5 mm glass tube, 589 ± 1 mm nominal length, G13 caps at both ends — so the questions that actually decide a retrofit sit elsewhere. These are the five we ask about first.
1. Does the length clear the housing, pins included?
The lamp body is 589 ± 1 mm, but the maximum overall length including the pins is 604 mm, on a Φ25.5 ± 0.5 mm tube weighing 110 g ± 10%. In a sheet-metal trap with tight end plates or a sliding lamp door, the 604 mm figure is the one that has to fit. Measure the internal span between the lampholders, not the old lamp alone: holder depth varies between trap models.
2. How is the fixture wired — both ends or one?
The standard build is a double-end input lamp, and a single-end input version is available as an option. This matters because trap fixtures differ: some feed both lampholders, others only bring live and neutral to one side. Confirm which pattern the existing trap uses before specifying, and check how the fixture handles the ballast or choke of the lamp being replaced — the LED tube carries its own non-isolated constant-current supply and is rated for AC 100–240 V at 50/60 Hz, so it expects mains at its input rather than the output of a lamp ballast.
3. Which way does the light face?
The luminous surface of a T8 LED tube is a strip, not a full circle, so the mounting angle determines where the UV goes. On the standard lamp the luminous surface is perpendicular to the square of the G13 pins; Tianhui also supplies a customized version with the luminous surface parallel to the pins. For a trap whose intake surface sits above or below the lamp, the two versions put the beam in different places — this is the single most common reason a retrofit under-performs, and it costs nothing to specify at the order stage.
4. Is the electrical budget still correct?
The lamp draws 45 mA ± 10% at AC 220 V with a power factor of 0.9 and a rated lamp power of 10 W ± 10%, so a multi-lamp trap adds up predictably on a shared circuit. Protection ratings are worth checking against site conditions too: 2.5 kV lightning surge capability and AC1500V/5 mA insulation withstand voltage for the lamp itself, with a UL94V-0 flame retardant rating on the assembly.
5. Will the environment stay inside the ratings?
The tube is rated for −20 °C to +45 °C operation at 10–90% RH, with storage from −20 °C to +85 °C. Enclosed traps in direct summer sun and unheated farm buildings are the two cases where the ambient figure needs a second look, because a sealed housing can sit well above the surrounding air temperature. Rated average life is ≥15,000 hours with light transmission maintenance of ≥L70 — useful when planning a replacement cycle across a fleet of traps rather than one unit.
What to expect from the output
Peak wavelength falls in the 360–370 nm range, centred at 365 nm, with 30 pcs of 2835 0.5 W single-band LEDs on an aluminium substrate producing ≥90 µW/cm² at one metre across a 120° emission angle. Those are the numbers to compare against the trap's own design distance and intake area; a lamp that is correct at one metre is not automatically correct at 300 mm, and vice versa.
Where the lamp is used
The same tube is specified for grocery stores, restaurants, shopping malls, farms and parks — environments where traps run for long hours, sit close to food handling or public areas, and are serviced by staff rather than technicians. RoHS compliance and the absence of a mercury fill are part of why LED retrofits are being scheduled into routine maintenance rather than treated as special projects.
Teams evaluating a swap can request the full specification sheet and samples of both the standard and horizontal-emission versions from the Tianhui sales team, and can send fixture drawings for a fit check before ordering.
Retrofit checklist at a glance